Controlled Impedance: 50, 90 and 100 Ohm Explained

At high edge rates a PCB trace stops behaving like a wire and starts behaving like a transmission line. If its impedance does not match the driver and the load, part of every edge reflects, and the result is ringing, eye closure and failed compliance tests. Controlled impedance means designing and building the trace to a specified value. This article covers the common targets and the geometry that produces them.

At a glance

50 Ω
The single-ended standard for RF and most high-speed single-ended signals.
90 Ω
Differential impedance required for USB 2.0 and USB 3.x pairs.
100 Ω
Differential impedance for Ethernet, LVDS, HDMI and most other pairs.
±10%
The usual manufacturing tolerance for controlled-impedance traces.

The problem

Impedance depends on trace width, the distance to the reference plane, the copper thickness and the dielectric constant of the laminate. Change any one and the impedance moves. A trace width copied from another board is wrong unless the stackup is identical.

The dielectric constant of standard FR-4 is not a single number either. It varies with the resin content of the specific prepreg and with frequency, which is why the fabricator, who knows the materials, should confirm the final geometry.

An impedance target without a stackup is a wish. The two have to be specified together.

What moves impedance

A wider trace or a thinner dielectric lowers impedance; a narrower trace or thicker dielectric raises it. For differential pairs, moving the two traces closer together lowers the differential impedance.

Keep the reference plane unbroken under the whole route. A trace crossing a split in the plane sees a jump in impedance and a much larger return loop, which is a common source of emissions failures.

What good looks like

Identify every net with an impedance requirement from the interface standards and device datasheets, and record the target and tolerance.

Calculate trace geometry for your stackup with a field-solver tool, then send the targets to the fabricator and use the widths they confirm.

Add the impedance table to the fabrication drawing and request test coupons if the design needs measured evidence.

Common impedance targets
InterfaceTypeTarget
RF, antenna feedSingle-ended50 Ω
USB 2.0 / 3.xDifferential90 Ω
Ethernet (100/1000BASE-T)Differential100 Ω
LVDS, HDMI, DisplayPortDifferential100 Ω
CAN busDifferential120 Ω
DDR3 / DDR4 dataSingle-ended40-50 Ω
Values from the interface standards. Always confirm against the device datasheet.
Differential impedance by interface
Ω
USB90
Ethernet100
LVDS100
HDMI100
CAN120
Nominal differential impedance specified by each standard.

What it changes

Signal Quality

Matched traces deliver clean edges, which is what interface compliance testing measures.

First-Pass Success

Impedance agreed with the fabricator before layout avoids a respin for a parameter that could not be met.

EMC

Unbroken reference planes keep return currents under their signals and loops small.

Repeatability

A documented impedance table makes every later build match the first.

Where to go next

For lengths that are a small fraction of the signal wavelength, impedance control matters much less. Short, slow traces do not need it.

For radio traces, also follow the reference layout from the module or chip vendor closely. Antenna matching depends on more than the trace impedance.

Problems this prevents

  • Trace widths copied from a different stackup
  • High-speed routes crossing plane splits
  • Impedance left off the fabrication drawing
  • Compliance failures found only at the test lab

Discuss your project