EMC Limits Explained: FCC Class A and Class B
Electronic products emit radio-frequency energy whether or not they contain a radio, and regulators limit how much. In the United States the rules for unintentional radiators are in FCC Part 15. Products are classed by where they are used, and the limits differ. Failing at the test lab is one of the most common causes of a late launch, and most failures trace back to decisions made during schematic and layout.
At a glance
- Class B
- Limits for products used in homes. The stricter of the two classes.
- Class A
- Limits for products used only in commercial and industrial settings.
- 30 MHz
- Radiated emissions are measured from 30 MHz upward; conducted emissions below it.
- 3 m
- The measurement distance for Class B radiated limits. Class A is specified at 10 m.
The problem
Emissions are not visible in normal testing. A board can pass every functional test and still radiate far above the limit from a clock harmonic, a switching regulator or a cable acting as an antenna.
Fixes applied after a failure are expensive and crude: ferrites, shielding cans, a respun board. The causes are usually structural, such as a return path broken by a plane split or a noisy signal routed to a connector.
Emissions are designed in or designed out during layout. The test lab only tells you which.
Designing to pass
Keep high-speed signals over an unbroken ground plane, keep switching-regulator loops small, and filter every line that leaves the board at the point where it leaves. Cables are the most effective antennas on most products.
Run a pre-compliance scan on an early prototype. It costs far less than a formal test and shows whether the design is close to the limit or far over it, while there is still time to change it.
What good looks like
Decide which class applies from where the product will be used and sold, and note the limits for every target market.
Apply layout practices that control return paths, loop areas and cable filtering from the first schematic.
Scan a prototype for emissions before the design is frozen, and book the formal test only when the scan shows margin.
| Frequency | Class A at 10 m | Class B at 3 m |
|---|---|---|
| 30 - 88 MHz | 39.1 dBµV/m | 40.0 dBµV/m |
| 88 - 216 MHz | 43.5 dBµV/m | 43.5 dBµV/m |
| 216 - 960 MHz | 46.4 dBµV/m | 46.0 dBµV/m |
| Above 960 MHz | 49.5 dBµV/m | 54.0 dBµV/m |
| Class A | Class B | |
|---|---|---|
| Where used | Commercial, industrial | Residential |
| Stringency | Less strict | Stricter |
| Measurement distance | 10 m | 3 m |
| Sold to consumers | No | Yes |
What it changes
Schedule
Passing first time removes one of the most common late-stage delays.
Unit Cost
Emissions controlled by layout need no added shields or ferrites.
Market Access
A compliant design can be sold legally in its target markets.
Robustness
The practices that reduce emissions also improve immunity to interference.
Where to go next
Products containing a radio transmitter fall under additional rules for intentional radiators. A pre-certified module simplifies that part considerably.
Other markets have their own requirements. The European Union, for example, applies harmonised standards under its EMC and radio equipment directives.
Problems this prevents
- Emission failures found at the formal test
- Noisy signals routed straight to connectors
- Return paths broken by plane splits
- Shields and ferrites added to every unit