Trace Width and Current: How Wide Is Wide Enough?

Every trace has resistance, and current through resistance makes heat. The question for a power trace is not whether it warms up but by how much. IPC-2221 provides an empirical formula relating current, cross-sectional area and temperature rise, and it remains the usual starting point for sizing traces. This article gives calculated widths for common currents and explains when to be more conservative.

At a glance

10 °C
A common design limit for trace temperature rise above ambient.
2.6x
Internal traces need about 2.6 times the width of external ones for the same current and rise.
1 oz
Standard copper weight. Moving to 2 oz halves the width needed.
IPC-2221
The generic design standard whose chart most trace calculators implement.

The problem

Signal traces are sized for routing density, and it is easy to leave a power trace at the same width. At a few hundred milliamps nothing visible happens. At a few amps the trace temperature rises, its resistance rises with it, and the voltage arriving at the load sags.

Internal layers are worse. They are surrounded by laminate, a poor thermal conductor, so they shed heat far less effectively than an outer layer exposed to air.

Size power traces for temperature rise first, then check the voltage drop. Either one can be the limit.

Reading the numbers

The table below applies the IPC-2221 formula for a 10 °C rise. The formula is conservative for boards with nearby copper planes, which spread heat, and optimistic for a trace isolated in a hot enclosure. Treat the result as a minimum and round up.

For high currents, check voltage drop separately. A long, adequately cool trace can still lose more voltage than the load can accept, in which case a pour or a plane is the right answer.

What good looks like

List every net carrying significant current, with its worst-case continuous value and the layer it will be routed on.

Calculate the minimum width for your chosen temperature rise and copper weight, then widen it as far as the layout allows.

Check voltage drop on long runs and size vias as well: one small via carries far less current than the trace feeding it.

Minimum trace width for a 10 °C rise
CurrentExternal, 1 ozInternal, 1 ozExternal, 2 oz
0.5 A0.12 mm0.30 mm0.06 mm
1 A0.30 mm0.78 mm0.15 mm
2 A0.78 mm2.03 mm0.39 mm
3 A1.37 mm3.56 mm0.68 mm
5 A2.77 mm7.19 mm1.38 mm
Calculated with the IPC-2221 formula. Treat as a minimum and round up.
External 1 oz trace width by current
mm
0.5 A0.12
1 A0.3
2 A0.78
3 A1.37
5 A2.77
IPC-2221, 10 °C rise. Width grows faster than current.

What it changes

Reliability

Traces that run cool do not age the laminate or stress solder joints around them.

Voltage Margin

Adequate copper keeps the supply at the load within the range the device needs.

Safety

Correctly sized traces behave predictably under fault currents instead of acting as fuses.

Cost

Knowing the real requirement shows when 1 oz copper is enough and when 2 oz is justified.

Where to go next

Use pours and planes for the highest currents. They lower resistance and spread heat far better than a wide trace.

Where current passes between layers, use several vias in parallel and keep them close to the source and load.

Problems this prevents

  • Power traces left at signal width
  • Internal traces sized with external-layer rules
  • A single small via in a high-current path
  • Voltage drop that was never calculated