Via Types Explained: Through-Hole, Blind, Buried and Microvias

A via is a plated hole that connects copper on different layers. On most boards every via is drilled straight through, which is the cheapest way to build them. Dense designs, particularly those with fine-pitch BGAs, run out of space for through vias and turn to blind, buried and microvias. Each adds process steps and cost. This article explains the types, how they are made, and the protection options for vias near or in pads.

At a glance

Through
Drilled through the whole board after lamination; the cheapest and most common via.
Blind
Connects an outer layer to one or more inner layers without passing through.
Buried
Connects inner layers only and cannot be seen from either surface.
1:1
The maximum aspect ratio in the IPC definition of a microvia, which is usually laser drilled.

The problem

A through via occupies every layer of the board, including layers where it carries no signal. Under a fine-pitch BGA those holes and their clearances consume the space needed to route signals out, and above a certain density there is no room left.

Blind, buried and microvias solve the routing problem but change how the board is built. Each set of blind or buried vias can need its own drilling and lamination cycle, and every extra cycle adds cost, lead time and yield risk.

Use the simplest via structure that routes the board. Each step beyond through vias should be justified by a part that needs it.

Vias in and near pads

Placing a via directly in a component pad saves space and shortens connections, but an open via wicks solder away from the joint during reflow. Via-in-pad therefore needs the via filled and plated over, so the pad is flat and solid.

IPC-4761 defines a set of via protection types, from vias tented with solder mask to vias that are filled and capped. Stating the type on the fabrication drawing removes any ambiguity about how vias are to be finished.

What good looks like

Check whether the densest part on the board can be escaped with through vias using your fabricator’s standard rules.

If not, agree the least complex structure that works with the fabricator, such as one layer of microvias on each side, before committing.

State via types, layer spans, fill and protection requirements explicitly on the fabrication drawing.

Via types at a glance
TypeConnectsHow madeRelative cost
ThroughTop to bottomMechanically drilled after laminationLowest
BlindOuter layer to inner layerControlled-depth or laser drilling, or drilled before laminationHigher
BuriedInner layers onlyDrilled in a sub-laminate before final laminationHigher
MicroviaAdjacent layers, aspect ratio up to 1:1Usually laser drilledHigher, rising with stacked layers
General characteristics. Capabilities and relative costs vary by fabricator.
IPC-4761 via protection types
TypeNameDescription
ITentedDry film mask spans the hole
IITented and coveredTented, then covered with liquid mask
IIIPluggedPlugging material partly into the hole
IVPlugged and coveredPlugged, then covered with liquid mask
VFilledHole fully filled with material
VIFilled and coveredFilled, then covered with liquid mask
VIIFilled and cappedFilled, then plated over; used for via-in-pad
Type names from IPC-4761. Confirm which types your fabricator supports.

What it changes

Routability

Dense packages can be escaped without an excessive layer count.

Controlled Cost

Expensive structures are used only where needed.

Solder Joint Quality

Filled and capped via-in-pad avoids solder wicking.

Clear Fabrication Data

Specified via types leave nothing to interpretation.

Where to go next

Stacked microvias, placed directly on top of each other, are more demanding to build reliably than staggered ones. Discuss reliability requirements with the fabricator before stacking them.

Back-drilling removes the unused stub of a through via and is an option for high-speed signals where via stubs cause reflections.

Problems this prevents

  • BGAs that cannot be escaped with through vias
  • Paying for HDI structures the board does not need
  • Solder wicking into open via-in-pad holes
  • Via protection left unspecified on the drawing

Discuss your project

Email support@aavico.com or use Get in Touch when the website finishes loading.